Home >> Products >> Fluid Mechanics >> Water Tunnel and Water Channel >> LW-7962

LW-7962 Water Tunnel

Specifications
Horizontal Closed-Loop Structure
Can be set as an open channel structure
1. Test section: 30 (W) × 30 (H) × 200 (L) cm
2. Flow speed: 0.02 ~ 2 m/s
3. Turbulence intensity:
 a. As the speed lower than 0.1 m/s: within 2.5%
 b. As the speed 0.1~0.5 m/s: within 1%
 c. As the speed 0.5~2 m/s: within 0.5%
4. Speed uniformity: higher than 99%
5. Measuring area for the criteria above:
 a. For each cross section
 b. Effective area: 75% from the center of each cross section
6. Overall dimension: 7 (L) × 2 (W) × 1.8 (H) m (Ref.)


LW-7962 water tunnel