Home >> Products >> Thermal Solutions >> Thermal Wind Tunnel >> LW-9300T

LW-9300T Thermal Wind Tunnel

Specifications
1. Open-loop blow down structure
2. Test section dimension: 0.3 (W) × 0.3 (H) × 1.0 (L) m
3. Flow field quality:
3.1. Met over 80% of the cross-section area from axial center at 2 m/sec or up
at ambient condition
3.2. Uniformity >98%
3.3. Turbulence intensity <0.5%
4. Speed range:
4.1. 0.2 ~ 5 m/sec under heating condition
4.2. 0.2 ~ 8 m/sec under ambient condition
5. Temperature range : ambient ~ 70℃
6. Wind tunnel dimension: 0.9 (W) × 6 (L) × 1.8 (H) m (Ref.)
7. Power source: AC220V, 3 phases, 100 Amp

LW-9300T Thermal Wind Tunnel


Contraction section
Contraction section

Test section
Test section